Level Controller MS 1
The NOLTA Level Controller MS1 is the ideal solution to control liquid levels with limited switching space, e.g. in:
- Pump stations
- Wells
- Pump chambers
Level Controller MS1 EX / MS1 EX C
The NOLTA Level Controller MS1 EX is the ideal solution to control liquids with limited switching space in potentially explosive atmospheres classified Cl.1 Div.1, (ATEX Zone 0, 1 or 2) e.g. in:
- Refineries
- Gas stations
- Sewage works
Level Controller MS1 C
The NOLTA Level Controller MS1 C is the ideal solution to control liquids with limited switching space. For example in:
- Chemical plants
- Electro plating
- Purifying plants
Level Controller MS1 H
The NOLTA Level Controller MS1 H is the ideal solution for halogen-free installations, e.g. in:
- Hospitals
- Public institutions
- Chemical plants
Level Controller MS1 S
The NOLTA Level Controller MS1 S for use in high temperature environments e.g. in
- Galvanization
- Cement plants
- Chemical applications
Level Controller MS1 ACS
The NOLTA Level Controller MS1 ACS is the ideal solution to control liquids with high hygienic requirements. For example in:
- Wells
- Bottling plants
- Potable water reservoirs
Level Controller MS1 UL
The NOLTA Level Controller MS1 UL for use in North America, e.g. in:
- Treatment plants
- Pump stations
- Lift stations
Level Controller M2
The NOLTA Level Controller M2 is the ideal solution to control liquids with very limited switching space. For example in:
- Constricted diameters
- Narrow hoppers
- Small tanks
Level Controller M3
The NOLTA Level Controller M3 is the ideal solution to control liquid levels with limited switching space, e.g. in:
- Barrels
- Silos
- Tanks
Float Switch N1
The NOLTA Float Switch N1 is the ideal solution to control the level of most diverse liquids, for example in:
- Construction site dewatering
- Industrial filling plants
- Pit draining
Float Switch N1 pro
The NOLTA Float Switch N1 pro is the ideal solution to control liquid levels in industrial applications such as:
- Industrial waste water
- Emulsion of oils
- Dewatering
Float Switch KR1 EX
The NOLTA Float Switch KR1 EX is the ideal solution to control liquids in potentially explosive atmospheres classified Cl.1 Div.1, (ATEX Zone 0, 1 or 2) for example in:
- Gas stations
- Sewage works
- Fermentation plants
Float Switch KR1
The NOLTA Float Switch KR1 is the ideal solution to control liquid levels in industrial applications such as:
- Waste water
- Emulsion of oils
- Chlorine water
Float Switch KR1 S
The NOLTA Float Switch KR1 S is the ideal solution for hot fluids with little solid matter polution:
- Industrial wate water
- Chemical emulsions
- Temperatures occasionally reaching 100 °C
Level electrode KS1
The Level Electrode KS1 for level monitoring in conductive liquids in confined spaces. Labeled with MIN, MAX or without labeling available.
Accessories Water Technology
Cable support bracket
The stainless steel support bracket is mounted on the wall. With the 2 included M16 cable glands, one or two level controllers can be suspended freely at exactly the required height. Comes with screws and anchors (M 6).
Cable weight 700 g
The cable weight 41 03 weighs approximately 700g (1.5 lb) and can be used on all level controllers. The weight can be retrofitted on already installed controllers.
Cable Weight 300 g
The cable weight 40 00 weighs approximately 300g (0.7 lb) and can be used with NIVA level controller M2. Cable weight 40 01 weighs approximately 700 g (1.5 lb) and can be used with level controllers MS 1, N1 and KR1. Both weights must be fixed to the cable before installing the level controllers.
Cable Weight 160 g
The cable weight 40 05 weighs approx. 160g (0.35 lbs) and fits all Level Controllers M2 and M3. It can not be used with IECEx devices. The cable weight has to be fitted on the cable before installation of the controller. If required the M3 can also be supplied with a pre-mounted weight.
Intrinsically safe barrier
This 1-channel intrinsic safety barrier relay is an important safety measure for intrinsically safe electrical circuits. To ensure the safe disconnection of all intrinsically safe circuits in EX zones 0 and 1 (Cl.1 Div.1), a safety barrier relay is strictly required when installing EX-certified level controllers (EN 60079-11,14, 25 and EN 61241-11). One relay is required for each switching point (number of controllers in EX zone). Dual-channel barrier relays are available upon request.